¦¢ ORP Sensor (KDS-1039) ¦¢
¦¦
¦®   ¦¯
  ORP Sensor
The ORP sensor measures the ability of a solution to act as an oxidizing of reducing agent.
ORP stands for Oxidation-Reduction Potential also known as Redox Potential.

For more information,click 'Download' button.
 
¦±   ¦°
Download
¦£
¦¢ pH Sensor (KDS-1005) ¦¢
¦¦
¦®   ¦¯
  pH Sensor
pH Sensor can be used for experiment or gauging the pH value of acid, base solutions

For more informaion, click 'Download' button.
 
¦±   ¦°
Download
¦£
¦¢ Turbidity (KDS-1017) ¦¢
¦¦
   The Turbidity sensor is designed to measure the turbidity of fresh water or sea water.
   The Turbidity sensor measures turbidity in NTU.
   It is small, simple and easy to use and calibration can be done in about one minute.
   Also included is a high-grade glass cuvette for the water sample to be measured.
¦®   ¦¯
  Turbidity
¢¹ Range : 0~200 NTU
¢¹ Resolution : 0.25 NTU
 
¦±   ¦°
¦£
¦¢ Colorimeter¥± (KDS-1044) ¦¢
¦¦
¦®   ¦¯
  Colorimeter¥±
The Colorimeter¥± is designed to study the concentration of a solution by analyzing its color intensity.
The Colorimeter¥± measures the amount of light transmitted through a sample at a wavelength which user selected.
With the Colorimeter¥±, you can improve Beer's law. It has to be used with cuvette.
ScienceCube supplies 10cuvettes with the Colorimeter¥±.

For more information, click 'Download' button.
 
¦±   ¦°
Download
¦£
¦¢ DO Sensor (KDS-1022) ¦¢
¦¦
¦®   ¦¯
  DO Sensor
The DO(Dissolved Oxygen)Sensor can be used to measure the concentration of dissolved oxygen in water samples tested in the field or in the laboratory.
Since dissloved oxygen is one of the primary indicators of the quality of an aquatic environment, you can use this sensor to perform a wide variety of tests or experiments to determine changes in dissolved oxygen levels.

For more information, click 'Download' button.
 
¦±   ¦°
Download
¦£
¦¢ Oxygen Gas Sensor (KDS-1047) ¦¢
¦¦
   The Oxygen Gas Sensor measures the gaseous oxygen concentration in the range of 0 to 27%.
   It uses an electrochemical cell. The anode and cathode are immersed in an electolyte.
   When oxygen molecules enter the cell, they get electrochemically reduced at the cathode.
   This electrochemical reaction generates a current that is proportional to the partial pressure of oxygen
   in the gas mixture.
   The current is measured across a resistance to generate a small voltage output.
   The voltage output is amplified to the 0~5V output range.
¦®   ¦¯
  O2 sensor
¢¹ Range : 0~27% O©ü
¢¹ Output voltage range : 0~4V in air at 25¡É
sea level(standard) other range optional.
¢¹ Resolution : 0.03%(12bit)
 
¦±   ¦°
¦£
¦¢ Conductivity Probe (KDS-1038) ¦¢
¦¦
¦®   ¦¯
  Conductivity Probe
The Conductivity Probe can be used to measure either solution conductivity or total ion concentration of aqueous samples being investigated in the field or in the laboratory.
Conductivity is one of the easiest environmental tests of aquatic samples.